segunda-feira, 21 de novembro de 2011

error 1401 HP DATA PROTECTOR 4.0 SP1

Depois de muito me bater com uma unidade de fita HP com essa interface, toda hora gerando erro 1401 dizendo que a fita não é válida.

Workaround
For Windows:
  1. Close HP Data Protector Express.
  2. From the HP Data Protector Express backup server where the Encryption Kit is installed, open the dpdevice.ini file located in %SystemDrive%\Program Files\HP\Data Protector Express\config directory.
  3. Open the dpdevice.ini file for editing (using Notepad or a similar editor).
  4. Under the [class.scsi] section, add the following line:
    disableSecurityProtocol=Yes
  5. Save the dpdevice.ini file and exit the editor.
  6. Select Start > Run and enter services.msc , then click OK .
  7. Find the Data Protector Express service and click Stop .
  8. After the service has stopped, select the Data Protector Express service again, and click Start .
  9. After the Data Protector Express service has started, exit the Services window.
  10. Start HP Data Protector Express.

    perfeito!!